EasyManuals Logo

Fronius TransTig 800 Job User Manual

Fronius TransTig 800 Job
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #128 background imageLoading...
Page #128 background image
128
No protective gas shield
All other functions are OK
Cause: Gas cylinder is empty
Remedy: Change the gas cylinder
Cause: Gas pressure regulator is faulty
Remedy: Change the gas pressure regulator
Cause: Gas hose is not fitted or is damaged
Remedy: Fit or change the gas hose
Cause: Welding torch is faulty
Remedy: Change the welding torch
Cause: Gas solenoid valve is faulty
Remedy: Contact After-Sales Service
Poor weld properties
Cause: Incorrect welding parameters
Remedy: Check the settings
Cause: Grounding (earthing) connection is incorrect
Remedy: Check the grounding (earthing) connection and terminal for correct polarity
The welding torch becomes very hot
Cause: The dimensions of the welding torch are inadequate
Remedy: Observe the duty cycle and loading limits
Cause: Only on water-cooled machines: water flow is insufficient
Remedy: Check the water level, water flow rate, cleanliness, etc. If the coolant pump is
blocked: use a screwdriver - placed on the bushing - to turn the coolant pump
shaft
Cause: Only on water-cooled machines: C-C parameter is set to "OFF".
Remedy: In the set-up menu, set the C-C parameter to "Aut" or "ON".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 800 Job and is the answer not in the manual?

Fronius TransTig 800 Job Specifications

General IconGeneral
BrandFronius
ModelTransTig 800 Job
CategoryPortable Generator
LanguageEnglish

Related product manuals