SPECIFICATION SUMMARY
Type Function
UTY-
ALGXZ1
UTY-
PLGXA2
Option
UTY-
PLGXR2
Option
UTY-
PLGXE2
Option
UTY-
PLGXP2
Option
UTY-
PLGXX2
Option
Remark
System specication
Max. System Controller Lite per VRF
Network
1
Max. VRF networks supported 1
Max. indoor units / remote controller groups
per VRF network
400
Max. indoor units / remote controller groups
per System Controller Lite
400
Site supervision
Multiple sites display 10
2D/3D graphical layout view .
List display
z
Quick control from display available.
Tree display
z
Quick control from display available.
Operation
control
Individual
Start/Stop, Operation mode, Room
temperature
z
Fan speed, Airow direction
z
Economy mode
z
Antifreeze
z
Remote control prohibition setting
z
Temperature upper and lower limit setting
z
Filter sign reset
z
Human sensing
z
Schedule
Annual schedule
z
Week of year, day of month, day of
week setting.
Holiday special day settings.
Low noise mode weekly schedule
z
Outdoor unit control only.
Group
management
Number of groups 400
Group in group 3 Levels Lv.1 – 2 – 3.
Max. overlap denitions 400
1 unit may belong to up to 400
groups.
Auto generation
z
By site, building and oor.
Others
Memory operation
z
Operation pattern memorized and
reused.
Pattern operation
z
Reuse operation pattern once used.
Operation status
monitoring
Controlled status
z
See items controlled by operation.
Special operation
z
Defrost, Oil Recovery.
Room Temp. Room temperature
z
*
1
Error management
Error notication
z
Audible alarm
z
Error e-mail notication
z
History management
Error history 1 year
Operation control & status history 1 year
Energy saving
management
Indoor unit rotation
z
Outdoor unit capacity save
z
Peak cut control 1 month
Power consumption monitor
z
Electricity meters supported 200
Outdoor unit required per
connection
Power consumption information 3 years
Electricity charge
apportionment
Apportionment charge calculation
z
Apportionment charge bill creation
z
Tenant (block) setting 1600
Common facilities apportionment setting
z
Rated power consumption allotment setting
z
Electricity meters supported 200
Same meters used for energy
saving.
Electricity charge apportionment period 2 years
Prepaid air conditioning
z
Cooling and Heating information
z
Remote control
Internet, telephone line support
z
Max. client connection per server 5
Max. host connection from client 10
Data encryption
z
SSL used.
- (05 - 27) -
CONTROL
SYSTEM
CONTROL
SYSTEM

Table of Contents