TC : Total Capacity kBtu/h.
IP : Input Power kW (Compressor + Outdoor fan motor).
The data is based on the following conditions. Pipe length : 25 ft. (7.5 m) , Height dierence : 0 ft. (0 m).
COOLING CAPACITY
in kBtu/h
MODEL : AOU60RLAVM
z
Capacity : 60 kBtu/h (5 ton)
Total rated
cooling capacity
of indoor unit
Outdoor
temperature
Indoor temperature
68
°F
DB 59
°F
WB 73
°F
DB 61
°F
WB 75
°F
DB 63
°F
WB 79
°F
DB 64
°F
WB 80
°F
DB 67
°F
WB 82
°F
DB 68
°F
WB 86
°F
DB 72
°F
WB 90
°F
DB 73
°F
WB
(°FDB) TC IP TC IP TC IP TC IP TC IP TC IP TC IP TC IP
30.0
(50%)
23
19.0 1.25 21.8 1.39 24.5 1.53 25.9 1.61 30.0 1.82 31.4 1.89 36.9 2 .18 38.2 2.25
32
19.0 1.25 21.8 1.39 24.5 1.53 25.9 1.61 30.0 1.82 31.4 1.89 36.9 2 .18 38.2 2.25
41
19.0 1.25 21.8 1.39 24.5 1.53 25.9 1.61 30.0 1.82 31.4 1.89 36.9 2 .18 38.2 2.25
50
19.0 1.25 21.8 1.39 24.5 1.53 25.9 1.61 30.0 1.82 31.4 1.89 36.9 2 .18 38.2 2.25
59
19.0 1.25 21.8 1.39 24.5 1.53 25.9 1.61 30.0 1.82 31.4 1.89 36.9 2 .18 38.2 2.25
70
19.0 1.27 21.8 1.42 24.5 1.56 25.9 1.64 30.0 1.85 31.4 1.93 36.9 2.22 38.2 2.29
73
19.0 1.31 21.8 1.46 24.5 1.61 25.9 1.69 30.0 1.91 31.4 1.99 36.9 2.29 38.2 2.37
77
19.0 1.36 21.8 1.51 24.5 1.67 25.9 1.75 30.0 1.99 31.4 2.07 36.9 2.38 38.2 2.46
81
19.0 1.41 21.8 1.57 24.5 1.74 25.9 1.82 30.0 2.07 31.4 2.15 36.9 2.48 38.2 2.56
86
19.0 1.47 21.8 1.64 24.5 1.82 25.9 1.91 30.0 2.17 31.4 2.25 36.9 2.63 38.2 2.74
91
19.0 1.54 21.8 1.72 24.5 1.90 25.9 2.00 30.0 2.27 31.4 2.38 36.9 2.84 38.2 2.96
95
19.0 1.59 21.8 1.78 24.5 1.97 25.9 2.07 30.0 2.41 31.4 2.52 36.9 3.01 38.2 3.14
99
19.0 1.65 21.8 1.84 24.5 2.07 25.9 2 .19 30.0 2.55 31.4 2.67 36.9 3.19 38.2 3.33
104
19.0 1.73 21.8 1.97 24.5 2.22 25.9 2.34 30.0 2.73 31.4 2.87 36.9 3.43 38.2 3.57
109
19.0 1.85 21.8 2.11 24.5 2.37 25.9 2.51 30.0 2.93 31.4 3.08 36.9 3.69 38.2 3.85
115
19.0 2.00 21.8 2.28 24.5 2.58 25.9 2.73 30.0 3.20 31.4 3.37 36.9 4.05 38.2 4.23
- (02 - 20) -
MODEL
SELECTION
MODEL
SELECTION