RX100 S5 Operating manual 41
Hardware installation Installing/removing the server in/from the rac
k
4.2 Installing/removing the server in/from the
rack
V CAUTION!
Follow the safety instructions in chapter “Important information” on
page 25 and section “Rack installation instructions” on page 35.
The rack can tip over when more than one unit is removed.
V CAUTION!
The server does not have cable management in the rack.
Before removal, all cables connected to the server must be removed from
the sockets. Proceed as follows:
Exit all applications and shut down the operating system properly.
Switch off the server.
Disconnect and remove all cables connected to the server.
Remove the server.

Table of Contents

Other manuals for Fujitsu Primergy RX100 S5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu Primergy RX100 S5 and is the answer not in the manual?

Fujitsu Primergy RX100 S5 Specifications

General IconGeneral
Processor cache1 MB
Processor cores2
Processor familyIntel Pentium Dual Core
Processor frequency2.2 GHz
Processor cache typeL2
Processor front side bus800 MHz
Number of processors installed1
Hot-swapYes
HDD interfaceSerial ATA
Optical drive typeDVD Super Multi
Total storage capacity0 GB
Memory slots4
Internal memory1 GB
Internal memory typeDDR2-SDRAM
Maximum internal memory8 GB
Memory layout (slots x size)1 x 1 GB
Networking featuresGigabit Ethernet
USB 2.0 ports quantity5
Ethernet LAN (RJ-45) ports3
Power supply350 W
Power requirements100 - 127V/200 - 240V@50 - 60Hz
Redundant power supply (RPS) supportNo
Dimensions (WxDxH)430 x 560 x 42.5 mm
Compatible operating systemsMicrosoft Windows Server 2008/Server 2003, NovellSUSE Linux Enterprise Server, Red Hat Enterprise Linux
Chassis typeRack (1U)
Operating temperature (T-T)15 - 35 °C
Operating relative humidity (H-H)10 - 85 %
CertificationGS CE CSAc/us ULc/us FCC Class A CB RoHS WEEE VCCI CCC C-Tick BSMI
Weight and Dimensions IconWeight and Dimensions
Weight12000 g