66 Operating manual RX100 S5
Switching the server on and off Starting up and operation
Other On/Off options
In addition to the On/Off button, the server can be switched on and off in the
following ways:
– Specified switch on time / switch off time
The server is switched on or off at a time specified in the ServerView S2
program.
– Ring indicator
The server is switched on by an internal or external modem.
– Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
– After power failure
The server is automatically switched on following a power failure (depending
on the BIOS settings).
– Power button override
The server can be switched off immediately by pressing and holding the
On/Off button (approx. 4-5 sec.).
V CAUTION!
There is a risk that data may be lost.
– iRMC S2
iRMC S2 offers various options for switching the server on and off, e.g. via
the Power On Oss page of the iRMC S2 Web interface.