34 232003110G (03)
1.6 Operating Environment
Please follow the guidelines when considering a suitable location to set the LaserPro S400. Improper
work environments may lead to operational malfunction and/or unsafe working conditions. The
LaserPro S400 should be placed and operated in a standard office-type environment.
• Avoid environments where the machine is exposed to high level of dust, temperature
(temperature exceeding 30°C or 85°F) or humidity (humidity exceeding 70% or where the ambient
temperature is near the dew point).
• Avoid small, enclosed areas with poor ventilation.
• Avoid areas with high level of noise and electrical noise.
• Select a location that is large enough to accommodate the LaserPro S400, an exhaust system,
a computer and a work or storage table.
• Select a location in which the ambient temperature remains between 15°C and 30°C (60°F to
85°F).
• Select a location in which the relative humidity remains between 30% - 40%.
• Select a location in which there is a short, direct path to the fume exhaust system.
• Set the LaserPro S400 on a floor surface that is completely even.
• Make sure your smoke or fire detection system in the immediate area is functioning.
• Setup the machine to be apart from the wall for at least 60 cm (2 feet).
1.7 Noise Test
Test Conditions: measured at a distance of 1 meter from the surface of the machinery and a height of
1.6 meters from the floor or access platform.
S400 100W Sound Test Result: 70.2 dB