EasyManua.ls Logo

GE Multinet 4 - Logs: Global Settings

GE Multinet 4
318 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4–40 MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL
SYSTEM ADMINISTRATION CHAPTER 4: SYSTEM ADMINISTRATION
4.3.1.1 Logs: Global Settings
This screen enables you to specify the frequency, number, and size of log files.
FIGURE 4–24: Events: Logs: Global Settings
The table below specifies the valid values for fields of the Logs: Global Settings form.
Table 4–24: Logs: Global Settings
Field Name Field Value
Mode: The available values are:
Enabled – record events in the system log.
Disabled – do not record events in the system log (default).
Create New Log File: Indicates how often a new log file should be started, regardless
of the size of the current file. This parameter takes one of the
following values:
Daily: start a new log file at the beginning of each day
(default).
Weekly: start a new log file at the beginning of each week.
Monthly: start a new log file at the beginning of each
month.
When logging begins, a new file is created with the name
YYYYMMDDHHMMSS.log”.
Max Log Files: Specify the maximum number of log files to be preserved at any
one time.
Default value = 14.
Valid range= 1-100

Table of Contents

Related product manuals