4–50 MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL
SYSTEM ADMINISTRATION CHAPTER 4: SYSTEM ADMINISTRATION
4.4.1.4 Ports: Extended Statistics
To display this screen click a hyperlinked Port ID in the 4.4.1.3 Ports: Summary Statistics
screen. The Extended Statistics screen displays a detailed set of counters for each Ethernet
port in the system. The statistics may be re-loaded by clicking the Refresh button.
Table 4–30: Ethernet: Ports: Summary Statistics
Field Name Field Value
Port ID: Uniquely identifies an Ethernet interface.
Rx Packets: The total number of packets (including bad packets, broadcast
packets, and multicast packets) received.
Rx Octets: The total number of octets of data (including those in bad
packets) received on the network (excluding framing bits but
including FCS octets).
Tx Packets: The total number of packets (including broadcast packets and
multicast packets) transmitted.
Tx Octets: The total number of octets of data transmitted on the network
(excluding framing bits but including FCS octets).
CRC Errors: The total number of packets received that had a length
(excluding framing bits, but including FCS octets) of between 64
and 1518 octets, inclusive, but had a bad Frame Check
Sequence (FCS) with an integral number of octets.
All Errors: The total number of errors detected