2.4.2.2 Cleaning Optical Ports
These instructions are recommended only when there is evidence of contamination or
when reduced performance has been detected. Clean the optical ports as follows:
Z If required, remove the fiber optic connector from the optical port
and clean the connector as described in “Cleaning Connectors,
above.
Z Insert the extension tube, supplied with the canned air, into the
canned air nozzle and blow out the optical port. Use care not to
touch the bottom of the optical port.
Z Reconnect the fiber optic connector removed in step 1.
If degraded performance persists, perform the following additional steps:
Z Remove the fiber optic connector and place a dust cap on the end.
Z Using a small-head, lint-free swab gently wipe out the optical port.
Repeat steps 2 and 3 above.