MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL C–1
Multinet4 Multi-Port Serial Server
& Managed Switch
Chapter C: Modbus Memory Map
Digital Energy
Multilin
Modbus Memory Map
Address Qty Description Min Max Step Unit Format Default
0000 12 System Name - - - - String Varies
000C 12 System Contact - - - - String multilin.tech
@ge.com
0018 12 System Location - - - - String Markham,
Ontario
0024 6 Software Version - - - - String Varies
002A 1 IP Address[0] 0 255 1 - F1 0
002B 1 IP Address[1] 0 255 1 - F1 0
002C 1 IP Address[2] 0 255 1 - F1 0
002D 1 IP Address[3] 0 255 1 - F1 0
002E 1 NetMask[0] 0 255 1 - F1 0
002F 1 NetMask[1] 0 255 1 - F1 0
0030 1 NetMask[2] 0 255 1 - F1 0
0031 1 NetMask[3] 0 255 1 - F1 0
0032 1 GateWay[0] 0 255 1 - F1 0
0033 1 GateWay[1] 0 255 1 - F1 0
0034 1 GateWay[2] 0 255 1 - F1 0
0035 1 GateWay[3] 0 255 1 - F1 0
0036 3 MacAddress - - - - String Varies
0039 16 OrderCode - - - - String Varies
0049 1 PowerAlarm1 0 1 1 - F1 0
004A 1 PowerAlarm2 0 1 1 - F1 0