Appendix A. Performance Data
264 PACSystems* RX7i, RX3i and RSTi-EP CPU Reference Manual GFK-2222AD
A-2.4 RX7i Instruction Times
CPE010
CPE020
CRE020
94
CPE030
CRE030
94
CPE040
CRE040
94
Instruction
Enabled
(μs)
Disabled
(μs)
Enabled
(μs)
Disabled
(μs)
Enabled
(μs)
Disabled
(μs)
Enabled
(μs)
Disabled
(μs)
Enabled
(μs)
Disabled
(μs)
Bit Operation
AND_WORD
3.42
1.58
1.49
0.69
1.71
0.81
1.29
0.58
0.43
0.20
AND_DWORD
3.64
1.58
1.58
0.70
1.67
0.81
1.31
0.58
0.44
0.20
OR_WORD
3.58
1.71
1.56
0.76
1.72
0.90
1.28
0.59
0.43
0.20
OR_DWORD
3.55
1.66
1.54
0.73
1.71
0.83
1.44
0.60
0.48
0.20
XOR_WORD
3.42
1.57
1.48
0.69
1.73
0.80
1.29
0.61
0.48
0.25
XOR_DWORD
3.55
1.58
1.54
0.70
1.66
0.81
1.32
0.58
0.44
0.25
NOT_WORD
2.73
1.38
1.17
0.59
1.39
0.72
1.02
0.40
0.34
0.13
NOT_DWORD
2.81
1.44
1.21
0.62
1.44
0.75
1.07
0.41
0.35
0.14
MCMP_WORD
5.69
2.43
2.44
1.04
2.64
1.14
2.51
1.08
0.85
0.36
MCMP_DWORD
5.69
2.32
2.50
1.00
2.63
1.11
2.48
1.03
0.82
0.34
SHL_WORD
4.46
2.62
1.89
1.11
2.31
1.25
1.92
1.00
0.64
0.34
SHL_DWORD
4.53
2.73
1.92
1.56
2.31
1.28
1.90
0.98
0.63
0.32
SHR_WORD
4.64
2.59
1.96
1.09
2.45
1.24
1.98
0.98
0.66
0.32
SHR_DWORD
4.51
2.65
1.91
1.12
2.11
1.29
1.90
1.01
0.63
0.34
ROL_WORD
2.95
1.61
1.27
0.69
1.43
0.82
1.17
0.61
0.39
0.20
ROL_DWORD
3.27
1.61
1.39
0.70
1.46
0.84
1.07
0.59
0.36
0.20
ROR_WORD
2.93
1.52
1.25
0.66
1.45
0.82
1.11
0.57
0.39
0.19
ROR_DWORD
2.92
1.58
0.68
0.68
1.41
0.81
1.20
0.57
0.40
0.19
BTST_WORD
3.23
1.45
0.58
0.50
1.49
0.75
1.16
0.63
0.39
0.21
BTST_DWORD
3.29
1.37
1.41
0.50
1.48
0.72
1.19
0.63
0.40
0.19
BSET_WORD
2.62
1.43
1.12
0.61
1.17
0.72
0.97
0.48
0.31
0.16
BSET_DWORD
2.59
1.40
1.13
0.60
1.16
0.71
0.97
0.48
0.32
0.16
BCLR_WORD
2.51
1.36
1.08
0.59
1.20
0.72
0.97
0.48
0.31
0.16
BCLR_DWORD
2.49
1.33
1.07
0.57
1.16
0.70
0.97
0.47
0.32
0.16
BPOS_WORD
3.63
1.24
1.66
0.64
1.84
0.76
1.51
0.56
0.50
0.19
BPOS_DWORD
3.29
1.18
1.97
0.62
2.18
0.75
1.78
0.48
0.59
0.18
Relational
CMP_INT
3.51
1.25
1.50
0.54
1.45
0.60
1.58
0.52
0.53
0.17
CMP_DINT
3.86
1.32
1.66
0.57
1.51
0.66
1.61
0.52
0.53
0.17
CMP_REAL
3.65
1.30
1.57
0.56
1.52
0.62
0.53
0.53
0.54
0.10
CMP_LREAL
4.08
1.25
1.75
0.53
1.64
0.59
1.84
0.52
0.61
0.18
CMP_UINT
4.15
1.35
1.78
0.58
1.48
0.63
1.62
0.53
0.54
0.17
EQ_DATA
10.13
2.02
2.91
1.05
2.81
0.94
2.82
1.08
1.27
0.66
EQ_DINT
2.45
1.15
1.06
0.50
1.08
0.60
1.05
0.41
0.35
0.13
EQ_INT
2.49
1.14
1.07
0.50
1.04
0.58
1.04
0.47
0.35
0.16
EQ_LREAL
3.00
1.27
1.28
0.54
1.25
0.64
1.27
0.47
0.43
0.17
EQ_REAL
2.61
1.12
1.12
0.49
1.03
0.60
1.15
0.43
0.37
0.14
EQ_UINT
2.33
1.11
1.00
0.48
1.01
0.59
1.04
0.40
0.35
0.13
94
Due to Error Checking and Correction (ECC), Redundant CPU times are approximately 5% slower, on average, than the
equivalent Non-Redundant CPU.

Table of Contents

Other manuals for GE PACSystems RX7i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PACSystems RX7i and is the answer not in the manual?

GE PACSystems RX7i Specifications

General IconGeneral
BrandGE
ModelPACSystems RX7i
CategoryController
LanguageEnglish

Related product manuals