ADL300 • Quick installation guide - Specifications and connection 97
Step 4 - Setting encoder parameters (Standard card EXP-SESC-I1R1F2-ADL)
The incorrect conguration of the encoder tension can permanently damage the device; therefore, it is advisable to
check the values on the encoders specication plate.
En.
C8
Enter
21. 00.
Enter (x2)
20.4.8
2049 ppr
2047 ppr
Enter (x3s) Prg
21. 02.
Enter
88. 85
28 8.8
Enter
28 8.8
5.3 A
5.1 A
Enter (x3s)
At the end of the procedure proceed to step 6. Press the Prg x2 and keys.
Step 5 - Setting encoder parameters (Standard card EXP-SESC-I1R1F2-ADL)
ADL300 drives have a command to start automatic phasing of the absolute encoder (the brake must be blocked).
Phasing must be repeated whenever:
- the drive is replaced (alternatively, download parameters taken from previous drive)
- the motor is replaced
- the encoder is replaced
Note ! For more information see parameters 15.15 PAR 2190 Autophase rotation and 15.16 PAR 2192 Autophase still on "Functions description and parameters
list" manual (ADL300 Vector inverter for lifts with synchronous motors).
See section A.3.2 Phasing in the Appendix for further information.
PH.
AS
.
Enter
20.24.
Enter
8
E.
nt
.
Enter
do.nE.
C8 En.
88.8.0
...
8
6 5.ˉ
o8 En.
81.00.
do.nE.
(1) (2) (3) (4) (5)
(1) Press the Enter key to proceed to the autotune procedure.
(2) Press the Enter key to start the autotune procedure.
(3) Enable the drive by connecting terminal 9 on the I/O card (Enable) to terminal 12 (+24 V). To abort this operation,
press the Prg key.
(4) Once the drive is enabled the autotune procedure starts. This may take a few minutes, depending on the type of
motor being used.
(5) At the end of the procedure the following screen is displayed. After opening the Enable contact, proceed to step 6.
Press the Prg x2 and
keys.
Step 6 - Setting the maximum speed reference value and system speed
Setting the maximum speed reference value: this denes the maximum motor speed value (in rpm) that can be
reached with each single reference signal (analog or digital).
ΠS
P
d
Enter
86.80.
Enter (x2)
01.2.0
121 rpm
119 rpm
Enter (x3s) Prg
Set the maximum system speed in m/s
CS
P
d
Enter
10. 06.
Enter
88.81.
00.0.8
Enter
00.0.8
1.001 m/s
0.999 m/s
Enter (x3s) Prg
After setting the speed, proceed to step 7 to set the system weights. Press the Prg x3 and keys.
Note! The factory (default) setting depends on the size of the drive that is connected. These values refer to the ADL..-1055-BR
Caution

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran installationSIEIDrive ADL300 and is the answer not in the manual?

gefran installationSIEIDrive ADL300 Specifications

General IconGeneral
Brandgefran
ModelinstallationSIEIDrive ADL300
CategoryInverter
LanguageEnglish

Related product manuals