General Dynamics C4 Systems URC-200 (V2)
62
Table 13 – Transceiver Status Inquire Commands (Continued)
CODE NAME DESCRIPTION
?16
Power Level
Values
Returns value in the form: "&aaabbbcccdddeeefffggghhhiiijjjkkk"
aaa = AM Low value.
bbb = AM High value.
ccc = FM Low value.
ddd = FM Medium value.
eee = FM High value.
fff = AM high value at 115 MHz.
ggg = AM high value at 152 MHz.
hhh = AM high value at 174 MHz.
iii = AM high value at 225 MHz.
jjj = AM high value at 400 MHz.
kkk = AM high value at 420 MHz.
?17
Tuning Filter
Value
Returns value of the tuning filter pot. "}nnn" is the value returned
where:
‘nnn’ = a value from 0 - 255.
?18
Reserved
?19
30_90 Tone
Returns value in the form ">n"
n = 0 if receive and transmit tones are off.
= 1 if 150 Hz receive-tone is on.
= 2 if 150 Hz transmit-tone is on.
= 3 if both receive and transmit tones are on.
?20 to
?70
Deviation Values
Returns value in the form “Fxxx”
xxx = current value of that variable.
?71
Flat Slope Status
Returns "fx" where ‘x’ = 0 if pre-emphasis and ‘x’ = 1 if no pre-
emphasis is set.
?72
5 kHz Spacing
Returns value in the form: “nx”
x = 0 if 5 kHz spacing is disabled.
X = 1 if 5 kHz spacing is enabled.
?73
Startup Enable
Values
Returns the startup enable values as shown below:
“e.0a.1b-- where:
a = 0 if speaker is off.
= 1 if speaker is on.
b = 0 if display lamp is off.
= 1 if display lamp is at intensity level 1.
= 1 if display lamp is at intensity level 2.
= 1 if display lamp is at intensity level 3.