EasyManua.ls Logo

General Dynamics URC-200 (V2) - 5.3.2.2 FM CT Sensitivity

General Dynamics URC-200 (V2)
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Dynamics C4 Systems URC-200 (V2)
79
FM PT Distortion is displayed in percent in the Display area of the CRT screen. Verify
compliance with Table 1.
g. On both the URC-200 (V2) and the R2600 repeat steps A through F for preselect channels
2 through 9 and channel 0 on the URC-200 (V2) with the R2600 set on preset channel 10.
5.3.2.2 FM CT Sensitivity
1. Set up the test equipment as shown in Figure 16. Connect the
VERT/SINAD/DIST/DVM/COUNTER IN connector on the R2600 to Pin T (CT Out) of the
Remote connector. Pin A of the Remote connector is return ground.
2. Set the input power supply to 28 ± 1 VDC.
3. Preset the R2600 by performing the following steps.
a. Press the MEM (Memory) key on the R2600 panel for the preset-screen.
b. Use the CURSOR POSITION keys to highlight preset 01.
c. Press the "view preset" soft key.
NOTE
The soft keys are the eight keys under the CRT screen on the R2600.
d. Use the CURSOR POSITION keys to the Monitor Frequency position and enter 115.000
from the R2600 keypad.
e. Move the cursor to Modulation Type and press the "FM" soft key.
f. Move the cursor to the Generate Frequency position and enter 115.000 from the R2600
keypad.
g. Move the cursor to Modulation Type and press the "FM" soft key.
h. Move the cursor to bandwidth and press the "NARROW ±5 kHz" soft key.
i. Move the cursor to the Duplex Offset position and press the "DON'T CARE" soft key.
j. Move the cursor to Synth. Format Sel (synthesizer format select) and select the "Tone B"
soft key.
k. Move the cursor to Freq (frequency) and enter 08000.0 from the keypad.
l. Move the cursor to the DTMF Code position and press the "DON'T CARE" soft key.
NOTE
The “more” soft key may have to be depressed for the “DON”T CARE” soft
key to be displayed.
m. Press the "return" soft key. Repeat steps A through K for presets 02 through 10. Use
Table 21 to program the frequency presets in steps D and F above.
n. Press the "return" soft key.
4. Perform the following steps to complete the setup on the R2600 analyzer.

Table of Contents