April 2018 Maintenance Manual
Programmed Maintenance Procedures
Part No. 1268489GT S
®
Booms • Z
®
Booms 133
P0-5
Cummins Engine Maintenance Under 1000 Hours
Additional engine maintenance is required. Refer to the Programmed Maintenance Inspection Report for
the specific intervals that apply.
Required maintenance procedures and additional engine information are available in the manufacturer's
manuals. Refer to Specifications, Engine Operator and Maintenance Manuals.
Cummins B3.3T
Hour Intervals
Procedure
∅ =
Not required
Daily 250 500
Oil, fuel and coolant systems - check for leaks
Fuel-water separator - drain
Oil level - check
Coolant level - check
Drive belt - inspect
Cooling fan - inspect
Engine oil - replace
Oil filter - replace
Valve lash clearance - adjust (initial, one-time interval with oil change)
Air intake system - inspect
Air cleaner restriction - check
Fuel filter - replace
Fuel supply lines - vent
Injection pump - vent
Cooling system - check

Table of Contents

Other manuals for Genie Z Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Genie Z Series and is the answer not in the manual?

Genie Z Series Specifications

General IconGeneral
Lift Capacity500 lb (227 kg) to 660 lb (300 kg)
Gradeability30%
Power SourceDiesel, Electric
Capacity500 lb (227 kg) to 1, 000 lb (454 kg)
Drive System4-wheel drive
Tire TypeSolid
Steering2-wheel or 4-wheel

Related product manuals