Applications Zoom | 113
SET OUT The signs for the distance and angle differences are correction values (required
minus actual). The arrows indicate the direction to move to get to the set out
point.
NextPt
To add the next point to be set out.
Field Description
d HA Horizontal direction from the measured point to the set out point.
Positive if the telescope must be turned clockwise to the set out
point.
d.H.D Horizontal distance from the measured point to the set out point.
Positive if the set out point is further away than the measured
point.
d.d.Z Height difference from the measured point to the set out point.
Positive if the set out point is higher than the measured point.