ProfiLux 4 Resource Guide
EN 2018-13-11 45
Auto Top Off When a single sensor detects a low water level,
the Powerbar socket with the function,
Fill Water
, will turn on.
When normal water level is reached, the socket will turn off.
a. ATO Always active Checking this box will automate the
ATO function. Not having the box checked will require you
to create a timer function for this ATO. It is this timer
function which will dictate when the ATO function will be
enabled.
Leakage detection If a sensor is triggered, ProfiLux will
assume a leakage and trigger an alarm. By default, Powerbar
sockets with the function,
Fill Water
, stay ON with this function. If
a leakage is detected, the assigned sockets will turn OFF.
Return pump If a single sensor detects that the water level is
too high, the Powerbar socket with the function,
Fill Water
, is
turned ON. When normal water level is reached, the assigned
socket will turn OFF.
Min/Max control Two sensors are used to control a water
level. Sensor 1 (S1) works as the max-point and Sensor 2 (S2) is
the min-point. As soon as S2 detects a low water level, the
Powerbar socket with the function,
Fill Water
, is turned ON. When
normal water level is reached, the socket will turn OFF.
Water change Two sensors are used to perform water
changes. When a water change event is activated, the socket with
the function,
Drain Water
, will turn ON and stay ON until the
water level reaches sensor 2, min-point. The Powerbar socket with
the function,
Fill Water
, will then turn ON and stop when the
water level reaches Sensor 1, max-point.
ATO & Water change Works just like the water change
function, but also includes ATO function. With this mode, Sensor 1
serves a dual purpose, it becomes the ATO sensor and Max-point
sensor for AWC. When this sensor detects low water level, it will
turn on the Powerbar socket with the function,
Fill Water (ATO
only)
.
ATO 2 sensors Works just like a normal ATO function, but
instead uses 2 sensors to register the same water level. The
Powerbar socket with the function,
Fill Water
, will only turn on
when BOTH sensors register a low water level. Useful for
providing additional safety.
ii. Maximum On-time: This feature is used for setting the max on-time for
a specific sensor. If a sensor fails to deactivate the assigned function, the
corresponding Powerbar socket will shut OFF and an alarm will be
activated.

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C