This page provides an overview of all 64 controllable sockets and displays their current
states.
Double click on the desired Powerbar socket and a new window will pop-up. This
window is where you get to assign a specific function to the selected socket. Select the
function to assign, type-in a description, set a Blackout-delay if needed, click OK.
Blackout-delay: In case of a power outage, you can individually set each socket to
turn back ON after a period of time after the power has been restored. This feature is
useful for preventing skimmer overflows and more.
System 1-10V interface
All 1-10V devices that are to be controlled by the ProfiLux are first programmed through the 1-
10V interface settings page. Here is where you select an L-channel and assign the device to a
certain function.

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16