NOTE
In the
Filter off
column, you will see that the boxes are checked. A checked
box means that when a certain FP is activated, any powerbar outlet with the
corresponding function FILTER will be turned OFF. An unchecked box will
not affect those outlets.
ASSIGNING THE FUNCTION
1. Click on the (+) icon to the left of
System.
2. Select SWITCH CHANNELS AND OUTLETS.
3. Select the Powerbar outlet(s) that you’d like to react to this FP.
4. Set the function to FILTER and select the FILTER number you used when you created
the filter function.
For example, if you created the function on FEED PAUSE 1, set the function to
FILTER 1. If FEED PAUSE 2 was used, set the function to FILTER 2, etc.
5. Type-in a description in both fields, set a black-out delay if necessary, and then click OK.
6. Click SAVE CHANGES.

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C