7 ELECTRICAL ADJUSTMENTS
When inputting the recorded values
(9) If you have replaced the main board only, use the recorded values (The recorded values of X, Y,
XY(Z).).
Press the F2 key (X=) to input the X-axis distance adjustment value.
Press the F3 key (Y=) to input the Y-axis distance adjustment value.
Press the F4 key (XY=) to input the diagonal distance adjustment value (The recorded value of Z.).
Press the Up or Down arrow key to change the adjustment value.
(10) Press the Left arrow key after the adjustment values are input.
(11) Press the ENTER key to set the adjustment values.
(12) The following menu is displayed.
(13) Turn off the power.