CE6000-UM-251-9370 12-5
12 Target electrical component for WEEE instruction
• Removing (B) Pen Relay Board, CE6000
(1) Detach the right side cover.
(2) Disconnect the control panel exible cable from the main board.
(3) Remove the three M3L5 binding head screws holding the control panel assembly, and then detach
the control panel assembly.
M3L5 binding head screw
Control panel exible cable
Control panel assembly
(4) Remove the six M3L6 binding head screws holding the center cover, and then detach the center
cover.
M3L6 binding head screw
M3L6 binding head screw
Center cover
(5) Disconnect all the cables from the Pen-relay board.
Registration sensor cable
MC coil & encoder cable
Push roller sensor cable
Pen relay board
M3L6 binding head screw
Y exible cable