SK200-UM-251-9370 8-5
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
8.5 Front Guide Assembly
Detaching the front guide assembly
(1) Detach the top, left, right side side and front covers (see Sections 8.1, 8.2, 8.3 and 8.4).
(2) Remove the two M3L6 binding head screws holding the front guide assembly from each side.
Front guide assembly
M3L6 binding head screw
M3L6 binding head screw
(3) Detach the front guide assembly from the scanner unit.
Reattaching the front guide assembly
(1) Reattach the front guide assembly in the reverse order in which it was detached.