EasyManua.ls Logo

GRAPHTEC SK200-09 - Contact Glass Plate Assembly

GRAPHTEC SK200-09
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SK200-UM-251-9370 8-26
8. DISASSEMBLING AND ADJUSTING THE MECHANICAL PARTS
8.19 Contact Glass Plate Assembly
Detaching the contact glass plate assembly
(1) Detach the CIS sensor unit assembly (see Section 8.13).
(2) Remove the five M3L4 binding head screws holding the CIS sensor pressure bracket.
M3L4 binding head screw
(3) Loosen the two M3L8 set screws holding the CIS sensor.
(4) Detach the contact glass plate assembly.
Contact glass plate assembly
CIS sensor pressure bracket
CIS sensor unit
Reattaching the contact glass plate assembly
(1) Reattach the contact glass plate in the reverse order in which it was detached.
(2) Make sure that the CIS unit surface lies flat against the inside of the contact glass plate assembly when
you reattach the contact glass plate assembly.
(3) Perform the CIS sensor height adjustment (see section 8.18) and the software adjustment.
Checkpoint
When replacing the contact glass assembly, be sure to clean the interior of the image sensor unit and the inside of
the contact glass plate assembly. A soiled or dusty unit can affect scanning performance.