EasyManuals Logo

GW Instek PSU Series User Manual

GW Instek PSU Series
211 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
OPERATION
57
F-03
1 = CC High Speed Priority
3 = CC Slew Rate Priority
5. Press the Voltage knob to save the
configuration setting. ConF will be
displayed when it is configuring.
Voltage
VOLTAGE CURRENT
LAN RMT ERR DLY ALM ISR M 1 M 2 M 3 RUN
C V C C
V A
ISR indicator for CC Slew
Rate Priority (F-03=3)
6. If CC Slew Rate Priority was chosen as the
operating mode, set F-06 (Current Slew Rate
Up) and F-07 (Current Slew Rate Down) and
save.
F-06 / F-07
0.001A~2.000A / msec (PSU 6-200)
0.001A~1.800A / msec (PSU 8-180)
0.001A~1.200A / msec (PSU 12.5-120)
0.001A~1.000A / msec (PSU 15-100)
0.001A~0.760A / msec (PSU 20-76)
0.001A~0.500A / msec (PSU 30-50)
0.001A~0.380A / msec (PSU 40-38)
0.001A~0.300A / msec (PSU 50-30)
0.001A~0.250A / msec (PSU 60-25)
0.001A~0.190A / msec (PSU 80-19)
0.001A~0.150A / msec (PSU 100-15)
0.001A~0.100A / msec (PSU 150-10)
0.001A~0.025A / msec (PSU 300-5)
0.001A~0.008A / msec (PSU 400-3.8)
0.001A~0.006A / msec (PSU 600-2.6)
7. Press the Function key again to exit
the configuration settings. The
Function key light will turn off.
Function

Table of Contents

Other manuals for GW Instek PSU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek PSU Series and is the answer not in the manual?

GW Instek PSU Series Specifications

General IconGeneral
BrandGW Instek
ModelPSU Series
CategoryPower Supply
LanguageEnglish

Related product manuals