14 – 182 HEIDENHAIN Service Manual iTNC 530 HSCI
TNCremoNT
data transfer
software
For data transfer and data backup the HEIDENHAIN data transfer software TNCremoNT as of
version 2.7 is used in this description.
You can download the current version of TNCremoNT from the HEIDENHAIN website
(www.heidenhain.de) and install it on your laptop or stationary computer.
BINARY-to-ASCII
conversion
Some files (e.g., NC programs) on the data medium (HDR, SSDR) of the control are saved in BINARY
format.
Important advantages of this data format are the relatively fast access and the relatively low memory
requirements.
If the setting of the HEIDENHAIN data transfer software TNCremoNT is correct, data read from the
control to an external data medium (e.g. a laptop or a PC) is automatically converted from BINARY into
ASCII format.
When data is transferred from an external medium to the control, it is converted from ASCII format
into BINARY format.
The figure shows the correct setting in the TNCremoNT configuration:
Protection from
unauthorized
access
The machine manufacturer may have activated the soft key below on the iTNC 530 HSCI.
Before data are read from or written to the control, such an action must be approved.
8 Press the MOD key and subsequently the soft key EXTERNAL ACCESS ON/OFF.
--> Access must be permitted!
Note
Please use the most recent version of TNCremoNT.
Note
The TNCremoNT program includes detailed operating descriptions including a table of contents
in Menu/Help.
Note
The data of an iTNC 530 HSCI are archived externally in the defined ASCII format as the BINARY
format on the control may be changed, e.g., after an NC software update.
Note
Like internal access (at the control), the machine manufacturer may have locked external access
(via laptop/PC) to partitions on the control's data medium disk (e.g., PLC partition) with
passwords.
If necessary, ask the machine manufacturer!