21 – 350 HEIDENHAIN Service Manual iTNC 530 HSCI
Wiring overview
21.2.2 Machine parameters
MP100 is read from the right to the left and contains the information which axis is the first, the second,
the third, etc.
MP120 contains the assignment of the axes to the analog outputs (connectors X66 and X67
on the CMA-H).
MP121 contains the assignment of the spindles to the analog outputs (connectors X66 and X67
on the CMA-H).
MP1050 contains the analog voltage at rapid traverse (1.000 - 9.000 V).
21.2.3 Error messages
The following error messages may be displayed, if there are problems related to analog drives:
Movement monitoring
Nominal speed value too high
Excessive offset
Positioning error
Excessive servo lag
Standstill monitoring
MP100 must not be changed!
Other error messages may also indicate problems with an analog drive.