28 – 510 HEIDENHAIN Service Manual iTNC 530 HSCI
The adapter includes plug-in terminal strips for the contacts of the EMERGENCY STOP button and
permissive button (max. load 24 V; 1.2 A).
Internal wiring of the contacts for the EMERGENCY STOP button and permissive button:
28.14.2 HR 130 panel-mounted handwheel
The standard cable length for the HR 130 is 1 meter.
Pin layout for extension cable and handwheel:
Additional components ID
Dummy plug for EMERGENCY STOP circuit 271 958-03
Connecting cables
Spiral cable 312 879-01
Normal cable 296 467-xx
Metal armor tubing 296 687-xx
Plug-in terminal strips for advance ordering
3-pin terminal block 266 364-06
4-pin terminal block 266 364-12
Extension cable, ID 281 429-xx HR 130, ID 254 040-xx
D-sub cnnctr. (male)
9-pin
D-sub cnnctr.
(female) 9-pin
D-sub cnnctr. (male)
9-pin
Housing Shield Housing Housing Shield
2 White 2 2 White
4Brown44Brown
6 Yellow 6 6 Yellow
8 Green 8 8 Green
7Gray7