EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Handwheels

HEIDENHAIN iTNC 530 HSCI
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28 – 510 HEIDENHAIN Service Manual iTNC 530 HSCI
The adapter includes plug-in terminal strips for the contacts of the EMERGENCY STOP button and
permissive button (max. load 24 V; 1.2 A).
Internal wiring of the contacts for the EMERGENCY STOP button and permissive button:
28.14.2 HR 130 panel-mounted handwheel
The standard cable length for the HR 130 is 1 meter.
Pin layout for extension cable and handwheel:
Additional components ID
Dummy plug for EMERGENCY STOP circuit 271 958-03
Connecting cables
Spiral cable 312 879-01
Normal cable 296 467-xx
Metal armor tubing 296 687-xx
Plug-in terminal strips for advance ordering
3-pin terminal block 266 364-06
4-pin terminal block 266 364-12
Extension cable, ID 281 429-xx HR 130, ID 254 040-xx
D-sub cnnctr. (male)
9-pin
D-sub cnnctr.
(female) 9-pin
D-sub cnnctr. (male)
9-pin
Housing Shield Housing Housing Shield
2 White 2 2 White
4Brown44Brown
6 Yellow 6 6 Yellow
8 Green 8 8 Green
7Gray7