28.6 Digital I/O modules
28.6.1 Designations and positions of connectors
PLD-H 16-08-00
Positions of the
connectors
Connector Function
X11 PLC inputs, channel A
X12 PLC inputs, channel A
X21 PLC outputs, channel A
Diagnosis (meanings of the LEDs):
Red (X11/pin 1) status LED
Flashes: status of I/O module OK
Continuously on or off: error on I/O module
Yellow (per output): Status of the output
Error recognition:
Short circuit: A short circuit is reported when a current >= 20 A flows
for approximately 3 ms. Both the output-specific message and the
group message are modal.
After the short circuit has been removed, the PLC must reset the output
before it can be activated again.
PLD-H 08-16-00
Positions of the
connectors
Connector Function
X11 PLC inputs, channel A
X21 PLC outputs, channel A
X22 PLC outputs, channel A
Diagnosis (meanings of the LEDs):
Red (X11/pin 1) status LED
Flashes: status of I/O module OK
Continuously on or off: error on I/O module
Yellow (per output): Status of the output
Error recognition:
Short circuit: A short circuit is reported when a current >= 20 A flows
for approximately 3 ms. Both the output-specific message and the
group message are modal.
After the short circuit has been removed, the PLC must reset the output
before it can be activated again.
X11
X12
X21
X11
X21
X22