18 – 248 HEIDENHAIN Service Manual iTNC 530 HSCI
Flowchart
Switch off the machine, take precautions against
resetting and ensure that it is free of potential.
Open the housing side of the PSL 130.
Danger: There could still be residual voltage in
the power supply unit; do not touch any components!
Finding faults in PSL 130
The machine is on.
Carefully measure whether there are 400 V~ +/-10%
between L1 and L2 of the connector X33
(on the upper side of the PSL 130).
The PSL 130 is defective and must be replaced.
Yes
No
400 V~ available?
Yes
If connected: Carefully measure whether a dc-link
voltage (565V- +/- 10 % or 650 V-) is present at
the conductor bars of the PSL 130.
Uz available?
Yes
Shut down the control.
Check the fuses.
Fuses OK?
No
No
Restore the 400 V supply.
Restore the Uz supply.
Exchange the fuses as
described in this chapter.
Wait at least 5 minutes; then ensure again that
there is zero potential in the dc link.
Label the wires before disconnecting them,
and remove the PSL 130.