19 – 292 HEIDENHAIN Service Manual iTNC 530 HSCI
8 Observe the signal in the oscilloscope while traversing the X axis at low speed:
If signal evaluation is correct, a circle will be displayed.
If the display shows an oval, the scanning head is probably poorly adjusted or partly contaminated.