19 – 308 HEIDENHAIN Service Manual iTNC 530 HSCI
The A and B signals must be of equal size and move symmetrically about the same vertical axis
(no vertical offset)!
The 90° offset of the signals A and B on the horizontal axis is clearly visible.
The signals are displayed in mV.
8 Now you can switch the oscilloscope display to XY (Lissajous figure):