February 2012 21 – 329
On the UEC 11x there is a fixed assignment between the motor output, the input of the speed
encoder and the input of the position encoder:
UEC 111
Motor output Rated current at 5 kHz Speed input Position input
X80 20 A (spindle) X15 X201
X81 5 A X16 X202
X82 5 A X17 X203
X83 7.5 A (stronger axis) X18 X204
UEC 112
Motor output Rated current at 5 kHz Speed input Position input
X80 20 A (spindle) X15 X201
X81 5 A X16 X202
X82 5 A X17 X203
X83 7.5 A (stronger axis) X18 X204
X84 5 A X19 X205