February 2012 4 – 37
C340 Unknown
counter compnt.
%.2s
Hardware defective
Motor encoder defective
Incorrect software version
Check the software version.
Operate the motor at another encoder input.
Exchange drive-control board.
C350 Axis module
%.2s not ready
No pulse release for the power axis module
Uz too high
5-V power supply too weak
Inverter is not ready for operation
Motor control board defective
PWM cable defective
Noise pulses
Check the control and cabling of the pulse
release.
Check Uz.
For a non-regenerative power supply unit:
Is the braking resistor connected?
If the power supply is regenerative: Is the
energy recovery activated?
Check the grounding and shielding of the cable.
Exchange the power module.
For P controls: Exchange the interface card.
Exchange the motor drive-control board.
See ”Checking the enables on the iTNC 530
HSCI” on page 17 – 225.
See Service Manual Inverter Systems and
Motors.
C370 Angle error
motor enc. %.2s
Motor encoder defective
Motor encoder cable defective.
Drive control board defective
Check the motor encoder and leads.
Exchange the motor control board.
See ”Speed encoders” on page 19 – 300.
C380 Motor %.2s
not controllable
Motor cables were crossed (e.g. X with Y)
Motor encoder cable switched
Phases connected incorrectly to motor
Motor encoder cable defective
Incorrect motor table entry (direction of
rotation)
Motor defective
I2t monitoring has responded
Check the motor cabling.
Check motor and motor encoder cable.
Check motor table entry.
Check I2t monitoring (MP2302.x).
See ”Speed encoders” on page 19 – 300.
See Service Manual Inverter Systems and
Motors.
See
”Speed encoders” on page 19 – 300.
See
Service Manual Inverter Systems and
Motors.
C390 Error in 3-D
touch probe %.2s
Software error
Hardware error on drive-control board
Exchange the motor drive-control board.
Check the software version.
See ”Touch probes” on page 26 – 415.
C3A0 Incorrect
ref. position %.2s
Incorrect motor selected (MP2200)
Ground error on the motor encoder cable
(noise on Ref)
Motor encoder defective
Check the motor selection (MP2200).
Check the cabling of the motor encoder
(grounding).
Exchange the motor.
See ”Speed encoders” on page 19 – 300.
Error message Possible cause of error Measures for error diagnosis and/or