February 2012 28 – 471
X201 to X206:
Position encoder
with EnDat
interface
Pin layout:
CC 61xx Adapter cable
332 115-xx
Connecting cable
323 897-xx
Adapter cable
313 791-xx
Male Assignmt. Female Color Fem. Male Color Fem. Male Color Fem.
1+5 V (U
P
)1
Brown/
Green 7 7
Brown/
Green 7 7
Brown/
Green 5b
2 0 V (U
N
)2
White/
Green 10 10
White/
Green 10 10
White/
Green 6a
3A+ 3
Green/
Black 15 15
Green/
Black 15 15
Green/
Black 2a
4A– 4
Yellow/
Black 16 16
Yellow/
Black 16 16
Yellow/
Black 2b
5 Data 5 Gray 14 14 Gray 14 14 Gray 3b
6B+ 6
Blue/
Black 12 12
Blue/
Black 12 12
Blue/
Black 1a
7B– 7
Red/
Black 13 13
Red/
Black 13 13
Red/
Black 1b
8 Data
8 Pink 17 17 Pink 17 17 Pink 3a
9
+5 V
(sensor) 9 Blue 1 1 Blue 1 1 Blue 5a
10 Vacant 10 3 3 Red 3 3
11
0 V
(sensor) 11 White 4 4 White 4 4 White 6b
12 free 12 2 2 Black 2 2
13
Internal
shield 13
Internal
shield 11 11
Internal
shield 11 11
Internal
shield
14 Clock 14 Violet 8 8 Violet 8 8 Violet 4a
15 Clock
15 Yellow 9 9 Yellow 9 9 Yellow 4b
Hsg. Housing Hsg.
Ext.
shield Hsg.
Ext.
shield Hsg.
Ext.
shield
The interface complies with the requirements of EN50178 for "low voltage electrical separation."