February 2012 4 – 49
Relay external DC
voltage missing
Error message after power interruption Switch on the control voltage separately.
EMERGENCY STOP key pressed on machine
operating panel or handwheel
Axis is on hardware limit switch
Wiring interrupted
Relays, safety contactor combinations
defective
X34 is not powered with 24 V
"Control is ready" output of MC defective
Release the EMERGENCY STOP switch.
Retract the axis.
Check the EMERGENCY STOP chain. (See
”"Control is ready" output and input
(EMERGENCY STOP chain)” on page 17 – 228.)
If "Control is ready“ output is defective -->
replace the MC.
(See ”Exchange of HEIDENHAIN components”
on page 29 – 515.)
See ”Checking the enables on the iTNC 530
HSCI” on page 17 – 225.
Stylus already in
contact
The stylus is already deflected at the start of
probing movement.
Retract touch probe, repeat probing.
Inspect touch probe for damage.
See ”Touch probes” on page 26 – 415.
Exchange touch
probe battery.
Battery dead Replace the battery.
See ”Touch probes” on page 26 – 415.
Touch probe not
ready
The touch probe is not connected.
Battery dead
No connection between infrared probe system
and receiver unit.
Connect the touch probe.
Replace battery
Clean the receiver unit.
Penetration of humidity
Touch probe cable defective
Cable to transceiver unit defective
Contamination of probe and/or transmitter/
receiver unit --> No infrared connection
Obstacle in the infrared connection or strong
shading of transmitter or receiver
Several touch probes may be within the
receiving range of one SE; the infrared signals
cannot be allocated any more; faulty operation.
Interface to touch probe or transmitter/receiver
unit on MC defective
Dry the touch probe.
Replace the cable.
Clean touch probe and transmitter/receiver
unit.
Remove the obstacle in the infrared
connection.
R
eadjust receive range of SE.
If the interface to touch probe or transmitter/
receiver unit on the MC is defective --> replace
the MC. (See ”Exchange of HEIDENHAIN
components” on page 29 – 515.)
See ”Touch probes” on page 26 – 415.
TNC temperature
warning %dC
The temperature sensor in the control has
detected an excessively high temperature
inside the control housing. If the temperature
continues to increase, the control hardware
may be damaged.
Check the heat transfer in the electrical cabinet.
Check the fan in the control.
See ”Information menu” on page 18 – 261.
See ”Temperature” on page 6 – 74.
TNC temperature
too high %d°C
The temperature sensor in the LE has detected
an excessively high temperature inside the
control housing.
Check for adequate heat transfer in the
electrical cabinet.
Check the fan of the logic unit.
See ”Information menu” on page 18 – 261.
See ”Temperature” on page 6 – 74.
TS: Inadequate
consistency
During multiple measurement with the
automatic probe cycle the variance of the
individual measured values is greater than the
value defined in machine parameter MP6171.
Check whether the probe point and the stylus
are clean.
Increase the tolerance in MP6171.
See ”Touch probes” on page 26 – 415.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions
in the manual
Additional information and descriptions
in the manual