EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - PWM 9 encoder diagnostic kit

HEIDENHAIN iTNC 530 HSCI
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
February 2012 30 – 565
Available functions The PWM 9 functionality consists of the PWT MODE and the PWM MODE.
The most important functions of the PWM MODE:
Display of phase angle and on-to-off ratio
Display of scanning frequency
Measurement of signal amplitude, current consumption and supply voltage of the measuring
system
Display of internal universal counter and of encoder signal periods (pulse count)
Display of reference signal, fault-detection signal and counting direction
Output of the amplified scanning signals (11 µApp, 1 Vpp interface boards) or of the original scanning
signals (TTL, HTL interface boards) via 3 BNC sockets (e.g. to an oscilloscope)
The most important functions of the PWT MODE:
Graphic bar display of ...
Signal amplitude
Signal quality
Width of reference signal
Position of reference signal
Check-Ref function
Adjusting aid for mounting scanning heads of exposed encoders
Checking distance-coded reference marks
Note
Every PWM 9 is delivered with a detailed User's Manual.
This User's Manual is available on the Internet in German and other languages and can be
downloaded from www.heidenhain.de/...
During our training courses on measuring systems or special PWM 9 trainings the PWM 9 is
explained in detail.
We recommend that you participate in a HEIDENHAIN service training course so that you can use
the PWM 9 correctly and efficiently.
Contact HEIDENHAIN Traunreut or your regional agency.