31 – 610 HEIDENHAIN Service Manual iTNC 530 HSCI
MP6180 Coordinates of the ring gauge center for automatic calibration (Probing Cycle 2) with
respect to the machine datum (traverse range 1)
Input: 0 to +99 999.9999 [mm]
PLC
CN123
MP6180.0 X coordinate
MP6180.1 Y coordinate
MP6180.2 Z coordinate
MP6181 Coordinates of the ring gauge center for automatic calibration (Probing Cycle 2) with
respect to the machine datum (traverse range 2)
Input: 0 to +99 999.9999 [mm]
PLC
CN123
MP6181.0 X coordinate
MP6181.1 Y coordinate
MP6181.2 Z coordinate
MP6182 Coordinate of the ring gauge center for Probing Cycle 2 with respect to the machine datum
(traverse range 3)
Input: 0 to +99 999.9999 [mm]
PLC
CN123
MP6182.0 X coordinate
MP6182.1 Y coordinate
MP6182.2 Z coordinate
MP6185 Distance of probing point below ring top surface during calibration
Input: +0.001 to +99 999.9999 [mm]