February 2012 31 – 617
MP7237 Display and reset the operating times PLC
RUN
MP7237.0 Display PLC operating times
Input: Bits 0 to 12 represent PLC operating times 1 to 13
0: Do not display
1: Display
MP7237.1 Reset PLC operating times with code number 857282
Input: Bits 0 to 12 represent PLC operating times 1 to 13
0: Do not reset
1: Reset
MP7237.2 Reset NC operating times with code number 857282
Input: Bit 0 – No function
Bit 1 – "Machine on" operating time
Bit 2 – "Program run" operating time
0: Do not reset
1: Reset
MP7238.0-12 Dialog messages for PLC operating times 1 to 13
Input: 0 to 4095
Dialog no. from the file (OEM.SYS)
PLC
RUN
MP7245 Disable auxiliary cycles
Input: 0: Auxiliary cycles disabled
1: Auxiliary cycles permitted
PLC
RUN
MP7246 Machine parameter with multiple function
Input: %xxxx
Bit 0 – Paraxial positioning blocks
0: Permitted
1: Locked
Bit 1 – Clear with DEL key
0: Does not need confirmation
1: Must confirm via soft key
Bit 2 – Tool usage file
0: Do not generate
1: Generate
Bit 3 – Settings file for AFC
0: Do not generate
1: Generate
Bit 4 – ASCII file for machining time per NC block
0: Do not create ASCII file for machining time per NC block
1: Create ASCII file for machining time per NC block
PLC
RUN
MP7251 Number of global Q parameters starting from Q99 (up to Q60) that are transferred from
the OEM cycle to the calling program.
Input: 0 to 40
PLC
RUN
MP7260 Number of tools in the tool table
MP7260 can also be overwritten by the PLC and the LSV2 protocol.
Input: 0 to 30 000
CN123
MP7261.0-7 Number of pockets in the tool magazine 1 to 8
MP7261 can also be overwritten by the PLC and the LSV2 protocol.
Input: 0 to 9999
CN123
MP7262 Maximum tool index number for indexed tools
MP7262 can also be overwritten by the PLC and the LSV2 protocol.
Input: 0 to 9
CN123