8 – 86 HEIDENHAIN Service Manual iTNC 530 HSCI
INFO SOKY KEYSOURCE: Source of information on a key:
KEYBOARD
PLC
PLCNCSTART
HANDWHEEL
LSV2
KEYLOGGER
PROCESS: Name of the target process to which the key information is sent.
IDENT: Control-internal name of the soft key
SOFTKEY: Name of the BMX image file of the soft key
OVERLAY: Current overlay number of the soft key
Autorepeat ... Status information on the Autorepeat function (start, stop, waiting times, ...)
Key Logger: Status information on key recording (start, stop, repeat, ...)
INFO SYS WINEVENT
FILEMAN.STARTUP.READY
File manager (PGM MGT) started
ERROR "xxx": "yyy" "xxx": Name of the control process that enters the information in the log
PLC
SYS
MAIN
REMO
CTRL
SMARTNC
SMARTNC_LDF
BDEHAN
SOKY
GEO
PYTHON
FIXTURE
FILEMAN
“yyy“: Optional information: Name of the process causing the error
a. For test purposes, all LSV-2 telegrams can be entered in the log. After entering the code word LOGBOOK, this
function must be enabled with the LSV-2 TELEGRAM OFF/ON soft key.