12 Tables, Overviews and Dialogs
-..-
12.1 General User Parameters
30 Touch probes and digltizlng
Probing direction for measuring the radius with TT 120
MP6505 Positive probing direction in the angle reference axis (O” axis): 0
Positive probing direction in the +90” axis: 7
Negative probing direction in the angle reference axis (O” axis): 2
Negative probing direction in the +90” axis: 3
L
L
Probing feed rate for second measurement with TT 120, stylus shape, corrections in TD0L.T
MP6507 Calculate feed rate for second measurement with lT 120, with constant tolerance: +O
Calculate feed rate for second measurement with ll 120, with variable tolerance: +7
Constant feed rate for second measurement with TT 120: +2
TT 120 with cylindrical stylus: +O
TT 120 with cubic stylus: 44
Automatically send measuring results to TO0L.T: +O
Do not correct TO0L.T: +I.?8
Maximum permissible error when measuring rotating tool with TT 120
Required for calculating the probing feed rate in connection with MP6570.
MP6510 0.007 to 0.999 [mm1 (recommended: 0.005 mm)
Probing feed rate for lT 120 for stationary tool
MP6520 10 to 3 000 Imm/minl
Radius measurement with TT 120: Distance from lower edge of tool to upper edge of stylus
MP6530 0.001 to 9 999.9999 lmml
Rapid traverse for lT 120 in probe cycle
MP6550 10 to 10 000 fmm/minl
M function for spindle orientation when measuring single cutting edges with TT 120
MP6560 Oto88
Permissible rotational speed at circumference of milling tool when measuring rotating tools
MP6570 40.000 to 120.0000 tm/minl
Stylus center REF coordinates of TT 120
MP6580.0
MP6580.1
X axis: -99 999.9999 to 99 999.9999 fmml
Y axis: -99 999.9999 to 99 999.9999
[mm1
MP6580.2 Z axis: -99 999.9999 to 99 999.9999 [mm1
L
TNC 370