A.1 Power Requirements
The following table describes the A/C input power specification for the Ultrastar Data60.
Table 60: AC Power Specifications
Power
Alternating Current (AC) Power Supply (2 per enclosure)
Supply Rating: 80 PLUS Platinum rated
Max Power Consumption:~1250W
Wattage (per power supply)
Note: Max and Typical Power Consumption
values represent the output power to the
Typical Power Consumption:~1000W
system. Input power will vary depending on
the PSU efficiency and load sharing between
PSUs
200 - 240 VAC, auto-ranging, 50/60 HzVoltage (per power supply)
Maximum inrush current (per power supply)
Caution: The Ultrastar Data60 can only be plugged into highline. If the unit is plugged into lowline, the
PSU will report a "Critical" state when status pages are queried using SES. In this case, the enclosure
will power up, but the drives will not. The enclosure will remain in low-power mode.
A.2 Supported Operating Systems
A.3 List of Supported Server Components
Table 61: List of Supported CPUs
WattageL4 CacheCoresClock FrequencyProduct
85W13.75MB10 Cores2.20GHzIntel Xeon Silver
4114
105W16.5012 Cores2.30GHzIntel Xeon Gold 5118
212
A Site and System Operation Requirements
User Guide A.1 Power Requirements

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HGST Ultrastar Data60 H4060-J and is the answer not in the manual?

HGST Ultrastar Data60 H4060-J Specifications

General IconGeneral
BrandHGST
ModelUltrastar Data60 H4060-J
CategoryServer
LanguageEnglish

Related product manuals