HTTPS
Set the HTTPS for accessing the browser. Cercate is required when accessing.
Server
It refers to the port through which the client adds the device.
Report Strategy Sengs
You can set the center group for uploading the log via the ISUP protocol.
Go to Conguraon → Network → Basic Sengs → Report Strategy .
You can set the center group and the system will transfer logs via ISUP protocol. Click Save to save
the sengs.
Center Group
Select a center group from the drop-down list.
Main Channel
The device will communicate with the center via the main channel.
Note
N1 refers to wired network.
Set ISUP Parameters
Set the ISUP parameters for accessing device via ISUP protocol.
St
eps
Note
The
funcon should be supported by the device.
1. Click Conguraon → Ne
twork → Advanced Sengs → Plaorm .
2. Select ISUP from the plaorm access mode drop-down list.
3. Check Enable.
4. Set the ISUP version, server address, device ID, and the ISUP status.
Note
If you select 5.0 as the version, you should set the ISUP key as well.
5. Click Sa
ve.
DS-K1T341A Series Face Recognion Terminal User Manual