Loading...
Notes on the Graphical User Interface
11
RM GUI GRS
Release
8.0
09/2019
Clicking the button logs out the current user and displays the login page.
Displays the remaining time in seconds until the device automatically logs out an inactive user.
Clicking the button opens the
Device Security > Management Access > Web
dialog. There you can
specify the timeout.
When the configuration profile in the volatile memory (
RAM
) differs from the "Selected" configuration
profile in the non-volatile memory (
NVM
), this button is visible. Otherwise, the button is hidden.
Clicking the button opens the
Basic Settings > Load/Save
dialog.
By right-clicking the button you can save the current settings in the non-volatile memory (
NVM
).
When you position the mouse pointer over the button, a tooltip displays the following information:
Device Status:
This section displays a compressed view of the
Device status
frame in the
Basic
Settings > System
dialog. The section displays the alarm that is currently active and whose
occurrence was recorded first.
Security Status:
This section displays a compressed view of the
Security status
frame in the
Basic
Settings > System
dialog. The section displays the alarm that is currently active and whose
occurrence was recorded first.
Boot Parameter:
If you permanently save changes to the settings and at least one boot
parameter differs from the configuration profile used during the last restart, then this section
displays a note.
The following settings cause the boot parameters to change:
Basic Settings > External Memory
dialog,
Software auto update
parameter
Basic Settings > External Memory
dialog,
Config priority
parameter
Device Security > Management Access > Server
dialog,
SNMP
tab,
UDP port
parameter
Diagnostics > System > Selftest
dialog,
RAM test
parameter
Diagnostics > System > Selftest
dialog,
SysMon1 is available
parameter
Diagnostics > System > Selftest
dialog,
Load default config on error
parameter
Clicking the button opens the
Diagnostics > Status Configuration > Device Status
dialog.
Filter
The filter enables you to reduce the number of menu items in the menu. When filtering, the menu
displays only menu items matching the search string entered in the filter field.