13.3 Security Status
The Security Status provides an overview of the overall security of the device. Many processes aid
in system visualization by recording the security status of the device and then presenting its
condition in graphic form. The device displays the overall security status in the
Basic Settings >
System dialog,
Security status
frame.
In the
Global
tab of the
Diagnostics > Status Configuration > Security Status
dialog the device displays
its current status as
error
or
ok
in the
Security status
frame. The device determines this status from
the individual monitoring results.
The device enables you to:
Out-of-Band signalling using a signal contact
signal the changed security status by sending an SNMP trap
detect the security status in the
Basic Settings > System
dialog of the Graphical User Interface
query the security status in the Command Line Interface
13.3.1 Events which can be monitored
Specify the events that the device monitors.
For the corresponding parameter, mark the checkbox in the
Monitor
column.
Table 33:
Security Status
events
Name Meaning
Password default settings
unchanged
After installation change the passwords to increase security.
When active and the default passwords remain unchanged, the
device displays an alarm.
Min. password length < 8
Create passwords more than 8 characters long to maintain a
high security posture. When active, the device monitors the
Min.
password length
setting.
Password policy settings
deactivated
The device monitors the settings located in the
Device Security >
User Management dialog for password policy requirements.
User account password policy
check deactivated
The device monitors the settings of the
Policy check
checkbox.
When
Policy check
is inactive, the device sends an SNMP trap.
Telnet server active
The device monitors when you enable the
Telnet
function.
HTTP server active
The device monitors when you enable the
HTTP
function.
SNMP unencrypted
The device monitors when you enable the
SNMPv1
or
SNMPv2
function.
Access to system monitor with serial
interface possible
The device monitors the System Monitor status.
Saving the configuration profile on
the external memory possible
The device monitors the possibility to save configurations to the
external non-volatile memory.
Link interrupted on enabled device
ports
The device monitors the link status of active ports.
Access with HiDiscovery possible
The device monitors when you enable the HiDiscovery read/
write access function.
Load unencrypted config from
external memory
The device monitors the security settings for loading the
configuration from the external NVM.