EasyManua.ls Logo

Hirschmann GREYHOUND GRS1020 - Page 227

Hirschmann GREYHOUND GRS1020
619 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Switching
[ Switching > L2-Redundancy > FuseNet > Sub Ring ]
226
RM GUI GRS
Release
8.0
09/2019
5.9.5.1 Sub Ring
[ Switching > L2-Redundancy > FuseNet > Sub Ring ]
This dialog lets you set up the device as a subring manager.
The
Sub Ring
function enables you to easily couple network segments to existing redundancy rings.
The subring manager (SRM) couples a subring to an existing ring (base ring).
In the subring you can use any devices that support MRP as ring participants. These devices do
not require a subring manager function.
When setting up subrings, remember the following rules:
The device supports
Link Aggregation
in the subring
No spanning tree on subring ports
Same
MRP domain
on devices within a subring
Different VLANs for base ring and subring
Specify the VLAN settings as follows:
VLAN
X
for base ring
on the ring ports of the base ring participants
on the base ring ports of the subring manager
VLAN
Y
for subring
on the ring ports of the subring participants
on the subring ports of the subring manager
Note: To help avoid loops, only close the redundant line when the settings are specified in every
device participating in the ring.
Operation
Operation
Enables/disables the
Sub Ring
function.
Possible values:
On
The
Sub Ring
function is enabled.
Off
(default setting)
The
Sub Ring
function is disabled.
Information
Table entries (max.)
Displays the maximum number of subrings supported by the device.

Table of Contents