EasyManua.ls Logo

Hirschmann GREYHOUND GRS1020 - Page 539

Hirschmann GREYHOUND GRS1020
619 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation diagnosis
13.4
Out-of-Band signaling
199
UM Config GRS
Release
8.0
09/2019
In order to enable the device to monitor an active link without a connection, first enable the global
function, then enable the individual ports.
Perform the following steps:
signal-contact 1 monitor ring-
redundancy
Monitors the ring redundancy.
The signal contact opens in the following
situations:
The redundancy function becomes active (loss
of redundancy reserve).
The device is a normal ring participant and
detects an error in its settings.
signal-contact 1 monitor link-failure
Monitors the ports/interfaces link. When the link
interrupts on a monitored port/interface, the signal
contact opens.
signal-contact 1 monitor envm-removal
Monitors the active external memory. When you
remove the active external memory from the
device, the signal contact opens.
signal-contact 1 monitor envm-not-in-
sync
Monitors the configuration profiles in the device
and in the external memory.
The signal contact opens in the following
situations:
The configuration profile only exists in the
device.
The configuration profile in the device differs
from the configuration profile in the external
memory.
signal-contact 1 monitor power-supply 1
Monitors the power supply unit
1
. When the device
has a detected power supply fault, the signal
contact opens.
signal-contact 1 monitor module-removal
1
Monitors module
1
. When you remove module
1
from the device, the signal contact opens.
signal-contact 1 trap
Enables the device to send an SNMP trap when the
status of the operation monitoring changes.
no signal-contact 1 trap
Disabling the SNMP trap
In the
Monitor
column, activate the
Link interrupted on enabled device ports
function.
Open the
Diagnostics > Status Configuration > Device Status
dialog,
Port
tab.
enable
Change to the Privileged EXEC mode.
configure
Change to the Configuration mode.
signal-contact 1 monitor link-failure
Monitors the ports/interfaces link. When the link
interrupts on a monitored port/interface, the signal
contact opens.
interface 1/1
Change to the interface configuration mode of
interface
1/1
.
signal-contact 1 link-alarm
Monitors the port/interface link. When the link
interrupts on the port/interface, the signal contact
opens.

Table of Contents

Other manuals for Hirschmann GREYHOUND GRS1020