EasyManua.ls Logo

Hirschmann GREYHOUND GRS1020 - Page 545

Hirschmann GREYHOUND GRS1020
619 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation diagnosis
13.7
Auto-Disable
205
UM Config GRS
Release
8.0
09/2019
When the device disables a port due to threshold violations, the device lets you use the following
commands to manually reset the disabled port.
Perform the following steps:
In the
Action
column you can choose how the device reacts to detected errors. In this
example, the device disables port
1/1
for threshold violations and then automatically re-
enables the port.
To allow the device to disable and automatically re-enable the port, select the value
auto-disable
and configure the
Auto-Disable
function. The value
auto-disable
only
works in conjunction with the
Diagnostics > Ports > Auto-Disable
function.
The device can also disable a port without auto re-enabling.
To allow the device to disable the port only, select the value
disable port
.
To manually re-enable a disabled port, highlight the port.
Click the button and then the
Reset
item.
When you configure the
Auto-Disable
function, the value
disable port
also
automatically re-enables the port.
Open the
Diagnostics > Ports > Port Monitor
dialog,
Auto-disable
tab.
To allow the device to auto re-enable the port after it was disabled due to detected
threshold violations, mark the checkbox in the
CRC error
column.
Open the
Diagnostics > Ports > Port Monitor
dialog,
Port
tab.
Specify the delay time as 120 s in the
Reset timer [s]
column for the ports you want to
enable.
Note: The
Reset
item lets you enable the port before the time specified in the
Reset timer [s]
column counts down.
enable
Change to the Privileged EXEC mode.
configure
Change to the Configuration mode.
interface 1/1
Change to the interface configuration mode of
interface
1/1
.
port-monitor condition crc-fragments
count 2000
Specifying the CRC-Fragment counter to 2000
parts per million.
port-monitor condition crc-fragments
interval 15
Sets the measure interval to 15 seconds for CRC-
Fragment detection.
auto-disable timer 120
Specifies the waiting period of
120
seconds, after
which the
Auto-disable
function re-enables the port.
exit
Change to the Configuration mode.
auto-disable reason crc-error
Activate the auto-disable CRC function.
port-monitor condition crc-fragments
mode
Activate the CRC-Fragments condition to trigger an
action.
port-monitor operation
Activate the
Port Monitor
function.
enable
Change to the Privileged EXEC mode.
configure
Change to the Configuration mode.
interface 1/1
Change to the interface configuration mode of
interface
1/1
.
auto-disable reset
Lets you enable the port before the Timer counts
down.

Table of Contents

Other manuals for Hirschmann GREYHOUND GRS1020

Related product manuals