Operation Diagnostics
170
9.1
Sending traps
Basic - L3P
Release
3.1
06/07
Chassis encompasses the following events:
– Power Supply: The status of a supply voltage has changed (see the
System dialog).
– Signaling Relay: The status of the signal contact has changed.
To cosider this event enable “generate Trap” in the Diagno
stics:Signal Contact 1/2 Dialog.
An error has occurred in connection with the SNTP.
– A media module has been added or removed.
– The AutoConfiguration Adapter, ACA, has been inserted or removed.
– The value exceeded / fell below the temperature threshold.
Redundancy The status of the HIPER-Ring or the redundant coupling of HIPER-Rings
/ network segments has changed.
Port Security On one port a data packet has been received from an unauthorized
terminal device (see Port Security Dialog).
Bridge Although the BPDU guard function is activited at a port a BPDU was
received (see User Manual Redundancy under „Rapid Spanning Tree“).
Name Bedeutung
Table 13: Trap categories