BIOS FIRMWARE UPDATE INSTRUCTIONS
4-19
Out-of-band (OOB) means the FW update is performed remotely, User executes the
FW
update which the FW image and command will be delivered to BMC through the
network interface. BMC receives the command and image to perform the firmware
update.
Out-of-band (Offline) update (via YAFUFLASH tool)
Make sure the Server is powered off and keep the AC power source connected.
Connect one end of network cable to the Server BMC NIC port and the other end
to the remote client or server.
Unzip the release package to a folder in the remote client or server.
Remotely update the BIOS firmware through the BMC IP address (the default static
IP address is 192.168.0.120).
Linux environment:
Launch Terminal, change to the directory where the release package is located.
Enter the command “./ubios_ip.sh <BMC IP> XXX.bin”
Windows environment:
Launch a Command Prompt to the appropriate directory where the release package
is located.