BMC SMASH
5-16
Displays information for the board
show /sp
Reset BMC
reset /sp
Set server identify LED to be off
set /sp ServerIdentify=off
Set server identify LED to be on
set /sp ServerIdentify=on
Set server identify LED to be blinking
set /sp ServerIdentify=blinking
Q&A:
Q1: My system supports two po
wer supply slots and only one power supply unit con-
nected. What is the other power supply status?
A1: The other power supply status is " AllDeasserted ".
Q2: My system supports two power supply slots and two power supply units connected.
But only one power cord plugged. What is the other power supply status?
A2: The other power supply status shows "Presence Detected, Power Supply Input
Lost(AC/DC) ".
BMC Information
The BMC level commands provide several options to configure and display parameters of
the management agent.
Table 5.8: Targets and Actions
RELATED TARGETS
SUPPORTED ACTIONS
CD EXIT HELP CREATE DELETE SET SHOW RESET START STOP VERSION
/vvv v v
/sp v v v v v v v